Sercos-Ring not closed, fiber optics broken or intensity setting incorrect for length of cable (Switch S3 ) Diagnosis LEDs of the MotorController MC-4 pow (Control voltage display) Off: Control Voltage (24V) is missing or too low. buserr Off: Normal mode On : Bus error fiber optics e.g. err (error display) Off: normal mode Flashing with 0,5 Hz: fatal SERCOS error Flashing with 2 Hz: Error with reaction A, B or C On: serious error duringboot sequence. On: Normal mode Control voltage is within the limit Switches S1 and S2 With the switches S1 and S2 you adapt the addresses of the MC-4. Diagnosis LEDs of the MotorController MC-4 pow (Control voltage display) Off: Control Voltage (24V) is missing or too low. Cancelling boot sequence Hint: State of bus err-LED is not definded during boot sequence.
20V ) On : Normal mode err (Fehler) Off : Normal mode Flash 0,5 Hz: Fatal Sercos-error DiagnosisCode: x5xx Flash 2 Hz: Error reaction A, B or C See reference manual chapter 4.4 ‚Diagnosis classes and reaction‘ On : Fatal error during boot sequence e.g. Reset pow err buserr S1 x10 S2 x01 pow (Control voltage) Off : Control voltage is missing or too low ( 24V - 15% => ca.
The LED´s for Power, wd, err, Buserr are having the same meaning as on the MAx-4 (see page 3) DilMotion Control ELAU Training Center The interface is an open IEC interface, with the possibility to program the display when FW-Version >= So you can display your individual values like e.g. The LED´s for Power, wd, err, Buserr are having the same meaning as on the MAx-4 (see page 3) The Display of the Controllers Cx00 and P600 are showing the IP-Address and the FW – Version. 2 - Intensity) See Refernce manual chapter 3.1.6 DilMotion Control ELAU Training CenterĤ LED state of the C400, C600 and P600 C200 C400, C600 and P600Ĭontent of display is programmable Inquiry of keys via IEC program Diagnosis of the LED´s are according to MAx-4 The Display of the Controllers Cx00 and P600 are showing the IP-Address and the FW – Version. Sercos Ring not closed, fiber optics broken or intensity fiber optics not fit to length of cable (PLC configuration | RTB | No. buserr (Sercos bus error) Off : Normal mode On : Bus error fiber optics e.g. Press during the boot sequence ( err LED on) the reset button. Hereby the user files (PLCconfiguration and IEC program) are not considered. (see reference manual chapter and 4.2.2) Minimalboot of the Controller MAx-4 Is there a fatal error in the boot sequence the user can start a minimal boot. The Controller and the MotorController have control - and error LED´s which allow initial diagnosis even without Software.
Configuration file demaged or Minimal boot On : Fatal error during boot sequence e.g. 5xxx Flash 10 Hz: Boot sequece failed e.g. HW-error, processor is standing still => reset necessary err (error) Off : Normal mode Flash 1,7 Hz: Error class 1-5 active DiagnosisCode: 1xxx. 20V ) On : Normal mode wd (Watchdog) Off : Normal mode On : Fatal error e.g. Pow (Control voltage) Off: Control voltage is missing or too low ( 24V - 15% => ca.
PacDrive M PacDrive III Dilhan Don LiyanageĢ Content State LED´s State parameter of the PLC Configuration (PacDrive Diagnostics) Online help DiagnosisCode PD Diagnostics one of the best tools as can read from the controller and can’t write to it and hence can’t do any damage DilMotion Control